1000 hour test programme in a pressurised fluidised bed combustion facility. Volume II. Test data. Final report
Abstract
This is an appendix to a report on the operation and performance of pressurized fluidized bed combustors and their associated hot gas cleanup system with cyclone separators for use in a combined-cycle power plant. Each of 6 performance tests is described and the results for each test are given. For each test, data are presented on: combustor operating conditions; bed particle size distribution for both coal and dolomite feeds; heat and mass balances; sulfur retention; size and composition of particles in hot gas stream; and composition of solid wastes from combustor. (LCL)
- Research Org.:
- National Coal Board, Leatherhead (UK). Coal Utilization Research Lab.
- OSTI Identifier:
- 6148390
- Report Number(s):
- DOE/ET/10423-1102
ON: DE81030969
- DOE Contract Number:
- AC01-78ET10423
- Resource Type:
- Technical Report
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 20 FOSSIL-FUELED POWER PLANTS; COMBINED-CYCLE POWER PLANTS; FLUIDIZED-BED COMBUSTORS; HOT GAS CLEANUP; CYCLONE SEPARATORS; PERFORMANCE; AIR POLLUTION CONTROL; COAL; EXPERIMENTAL DATA; FLUIDIZED-BED COMBUSTION; FOSSIL-FUEL POWER PLANTS; PARTICLE SIZE; PARTICLES; CARBONACEOUS MATERIALS; CHEMICAL REACTIONS; COMBUSTION; COMBUSTORS; CONCENTRATORS; CONTROL; DATA; ENERGY SOURCES; EQUIPMENT; FOSSIL FUELS; FUELS; INERTIAL SEPARATORS; INFORMATION; MATERIALS; NUMERICAL DATA; OXIDATION; POLLUTION CONTROL; POLLUTION CONTROL EQUIPMENT; POWER PLANTS; PURIFICATION; SEPARATION EQUIPMENT; SIZE; THERMAL POWER PLANTS; THERMOCHEMICAL PROCESSES; 200104* - Fossil-Fueled Power Plants- Components; 200102 - Fossil-Fueled Power Plants- Power Cycles; 200202 - Fossil-Fueled Power Plants- Waste Management- Noxious Gas & Particulate Emissions
Citation Formats
. 1000 hour test programme in a pressurised fluidised bed combustion facility. Volume II. Test data. Final report. United States: N. p.,
Web.
. 1000 hour test programme in a pressurised fluidised bed combustion facility. Volume II. Test data. Final report. United States.
. .
"1000 hour test programme in a pressurised fluidised bed combustion facility. Volume II. Test data. Final report". United States.
@article{osti_6148390,
title = {1000 hour test programme in a pressurised fluidised bed combustion facility. Volume II. Test data. Final report},
author = {},
abstractNote = {This is an appendix to a report on the operation and performance of pressurized fluidized bed combustors and their associated hot gas cleanup system with cyclone separators for use in a combined-cycle power plant. Each of 6 performance tests is described and the results for each test are given. For each test, data are presented on: combustor operating conditions; bed particle size distribution for both coal and dolomite feeds; heat and mass balances; sulfur retention; size and composition of particles in hot gas stream; and composition of solid wastes from combustor. (LCL)},
doi = {},
url = {https://www.osti.gov/biblio/6148390},
journal = {},
number = ,
volume = ,
place = {United States},
year = {},
month = {}
}
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that may hold this item. Keep in mind that many technical reports are not cataloged in WorldCat.
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.