{"authors": "bbloss,wmcalile,trevorirons,yaoguoli,snoripper62,", "creator_user_id": "acb1c858-8427-449f-af59-0b4a52e1d1c8", "id": "8ee5bb72-6ba6-4961-acd1-6c7a307da1b8", "maintainer": "Benjamin R Bloss", "maintainer_email": "bbloss@usgs.gov", "metadata_created": "2020-10-26T18:43:55.573610", "metadata_modified": "2020-12-04T16:38:08.795731", "name": "ground-based_transient_electromagnetic_data_and_resistivity_models_for_subter_bellecreek_2017-2018", "non_edx_author[]": ["Richard Krahenbuhl", "Michael D.M. Pace", "Katrina D. Zamudio"], "non_edx_email[]": ["rkrahenb@mines.edu", "mpace@usgs.gov", "kzamudio@usgs.gov"], "notes": "Ground-based transient electromagnetic (TEM) data were acquired in selected locations around Belle Creek, Montana to define the resistivity structure of the near surface. Data were acquired using the ABEM WalkTEM system (Guideline Geo Ab, Sundbyberg, Sweden). TEM data were processed and numerically inverted to derive one-dimensional resistivity structure using SPIA (Aarhus Geosoftware, Aarhus, Denmark).\r\n\r\nThis release includes raw and processed TEM data and resistivity models for each data location using the following structure:\r\n\r\n\u251c\u2500\u2500 Ground-based_transient_electromagnetic_data_and_resistivity_models_for_SubTER_BelleCreek_2017-2018.xml\r\n\u251c\u2500\u2500 SBC_TEM_2019_SoundingLocationsModels.gdb.zip - file geodatabase with all models and plots attached. This is a mirror of the contents of the model directory.\r\n\u2514\u2500\u2500 Ground-based_transient_electromagnetic_data_and_resistivity_models_for_SubTER_BelleCreek_2017-2018.zip\r\n \u251c\u2500\u2500 Data\r\n \u2502\u00a0\u00a0 \u251c\u2500\u2500 SBC_USF - raw data\r\n \u2502\u00a0\u00a0 \u2502\u00a0 \u251c\u2500\u2500 USF_format_description.pdf - manual describing the USF file format\r\n \u2502\u00a0\u00a0 \u2502\u00a0 \u251c\u2500\u2500 SBC_SoundingID-USF_lookup.csv - table describing the USF file naming convention and channel mapping\r\n \u2502\u00a0\u00a0 \u2502\u00a0 \u2514\u2500\u2500 *.usf files - raw, unprocessed data files\r\n \u2502\u00a0\u00a0 \u2514\u2500\u2500 SBC_TEM - processed data\r\n \u2502\u00a0\u00a0 \u00a0 \u251c\u2500\u2500 AarhusInv_manual.pdf - manual describing the TEM file format\r\n \u2502\u00a0\u00a0 \u00a0 \u2514\u2500\u2500 *.tem files - processed data files\r\n \u2514\u2500\u2500 Models\r\n \u251c\u2500\u2500 SBC_Model_Plots - plots of the data and the models for each sounding location\r\n \u251c\u2500\u2500 TEM_model_data_dictionary.csv - data dictionary describing tabulated models\r\n \u2514\u2500\u2500 SBC_TEM_models.csv - tabulated models\r\n", "num_resources": 0, "num_tags": 5, "package_reviewed": true, "poc_id": "e9ee7695-93c4-4ed5-9c0c-27b04c6344c7", "private": false, "state": "active", "title": "Ground-based_transient_electromagnetic_data_and_resistivity_models_for_SubTER_BelleCreek_2017-2018", "type": "dataset", "extras": [{"key": "citation", "value": "Benjamin R. Bloss, Wallace Anderson McAliley, Trevor Irons, Yaoguo Li, Nathan Moodie, Richard Krahenbuhl, Michael D.M. Pace, Katrina D. Zamudio, Ground-based_transient_electromagnetic_data_and_resistivity_models_for_SubTER_BelleCreek_2017-2018, 10/26/2020, https://edx.netl.doe.gov/dataset/ground-based_transient_electromagnetic_data_and_resistivity_models_for_subter_bellecreek_2017-2018, DOI: 10.18141/1686080"}, {"key": "netl_product", "value": "yes"}, {"key": "organization_extra", "value": "US Geological Survey"}, {"key": "osti", "value": "yes"}, {"key": "poc_email", "value": "Mary.Underwood@netl.doe.gov"}, {"key": "point_of_contact", "value": "Kylee Underwood"}, {"key": "program_or_project", "value": "SubTER"}, {"key": "project_number", "value": "FE0028320"}, {"key": "publication_date", "value": "2020-10-26"}, {"key": "spatial", "value": "{\"type\":\"MultiPolygon\",\"coordinates\":[[[[-105.0556219,45.13363189],[-105.0556219,45.10588456],[-105.1032751,45.10588456],[-105.1032751,45.13363189],[-105.0556219,45.13363189]]]]}"}], "groups": [{"description": "This is a group to bring together data resources related to all open carbon storage data on EDX", "display_name": "Carbon Storage Open Database", "id": "f316636f-1bd3-4713-b2e2-308d915490de", "image_display_url": "", "name": "carbon-storage-open-database", "title": "Carbon Storage Open Database"}], "resources": [{"id": "a10f2060-5060-4592-8b4f-aeea5fd6154a", "package_id": "8ee5bb72-6ba6-4961-acd1-6c7a307da1b8", "revision_id": "ffd965b1-e700-476d-978c-26ddf7c8371e", "url": "https://edx.netl.doe.gov/storage/f/edx/2020/10/2020-10-26T19:38:46.409Z/a10f2060-5060-4592-8b4f-aeea5fd6154a/netl_ground-based_transient_electromagnetic_data_and_resistivity_models_for_subter_bellecreek_2017-2018.xml", "format": "XML", "description": "", "hash": "md5:0a5ae88198a7deb370dc4776425f1e00", "position": 0, "name": "netl_ground-based_transient_electromagnetic_data_and_resistivity_models_for_subter_bellecreek_20.xml", "resource_type": "file.upload", "mimetype": "application/xml", "mimetype_inner": null, "size": 20500, "created": "2020-10-26T15:38:59.838000", "last_modified": "2020-10-26T15:38:59.838000", "cache_url": "storage/f/edx/2020/10/2020-10-26T19:38:46.409Z/a10f2060-5060-4592-8b4f-aeea5fd6154a/netl_ground-based_transient_electromagnetic_data_and_resistivity_models_for_subter_bellecreek_2017-2018.xml", "cache_last_updated": null, "url_type": "upload", "state": "active", "license_type": "notspecified", "folder_id": "root", "owner_org": null, "recycle_removed": false, "fgdc_metadata": false, "rating": null, "owner": "bbloss", "cache_url_updated": "2020-10-26T15:38:59.838", "datastore_active": false, "key": "2020-10-26T19:38:46.409Z/a10f2060-5060-4592-8b4f-aeea5fd6154a/netl_ground-based_transient_electromagnetic_data_and_resistivity_models_for_subter_bellecreek_2017-2018.xml", "revision_timestamp": "October 26, 2020, 19:39:00 (EST)", "intended_use_auth": false}, {"id": "25401e4e-a1fe-43ce-8f7d-cd90bb33b60c", "package_id": "8ee5bb72-6ba6-4961-acd1-6c7a307da1b8", "revision_id": "417166d4-9eac-4a91-ad05-65748ab5c1b1", "url": "https://edx.netl.doe.gov/storage/f/edx/2020/10/2020-10-26T19:17:02.175Z/25401e4e-a1fe-43ce-8f7d-cd90bb33b60c/ground-based_transient_electromagnetic_data_and_resistivity_models_for_subter_bellecreek_2017-2018.zip", "format": "ZIP", "description": "", "hash": "md5:fdb8748dbad55fd22c74d182744c518d", "position": 0, "name": "ground-based_transient_electromagnetic_data_and_resistivity_models_for_subter_bellecreek_2017-20.zip", "resource_type": "file.upload", "mimetype": "application/zip", "mimetype_inner": null, "size": 8533331, "created": "2020-10-26T15:17:17.622000", "last_modified": "2020-10-26T15:17:17.622000", "cache_url": "storage/f/edx/2020/10/2020-10-26T19:17:02.175Z/25401e4e-a1fe-43ce-8f7d-cd90bb33b60c/ground-based_transient_electromagnetic_data_and_resistivity_models_for_subter_bellecreek_2017-2018.zip", "cache_last_updated": null, "url_type": "upload", "state": "active", "license_type": "notspecified", "folder_id": "root", "owner_org": null, "recycle_removed": false, "fgdc_metadata": false, "rating": null, "owner": "bbloss", "cache_url_updated": "2020-10-26T15:17:17.622", "datastore_active": false, "key": "2020-10-26T19:17:02.175Z/25401e4e-a1fe-43ce-8f7d-cd90bb33b60c/ground-based_transient_electromagnetic_data_and_resistivity_models_for_subter_bellecreek_2017-2018.zip", "revision_timestamp": "October 26, 2020, 19:17:18 (EST)", "intended_use_auth": false}], "tags": [{"display_name": "Geophysics", "id": "54a251af-b285-458c-b4ea-999440cd528f", "name": "Geophysics", "state": "active", "vocabulary_id": null}, {"display_name": "geophysical surveying", "id": "8582c710-da30-40dc-b5b0-818cc0ae4dba", "name": "geophysical surveying", "state": "active", "vocabulary_id": null}, {"display_name": "near-surface mapping", "id": "621a912c-451f-4f8f-be65-476f55d10bd9", "name": "near-surface mapping", "state": "active", "vocabulary_id": null}, {"display_name": "time-domain electromagnetics", "id": "e57f637e-0df8-49f5-8336-ea132e585db1", "name": "time-domain electromagnetics", "state": "active", "vocabulary_id": null}, {"display_name": "transient electromagnetics", "id": "b6a53791-2ac2-415b-bdf1-ac12c2ebe4fa", "name": "transient electromagnetics", "state": "active", "vocabulary_id": null}], "osti": {"osti_id": "1686080", "site_code": "Energy Data Exchange", "dataset_type": "AS", "title": "Ground-based_transient_electromagnetic_data_and_resistivity_models_for_SubTER_BelleCreek_2017-2018", "creators": "Benjamin R. Bloss;Wallace Anderson McAliley;Trevor Irons;Yaoguo Li;Nathan Moodie;Richard Krahenbuhl;Michael D.M. Pace;Katrina D. Zamudio", "product_nos": "8ee5bb72-6ba6-4961-acd1-6c7a307da1b8", "contract_nos": "FE0028320", "org_research_org": "NETL", "publication_date": "2020-10-26", "language": "English", "country": "US", "sponsor_org": "USDOE Office of Fossil Energy (FE)", "site_url": "https://edx.netl.doe.gov/dataset/ground-based_transient_electromagnetic_data_and_resistivity_models_for_subter_bellecreek_2017-2018", "contact_name": "Benjamin R. Bloss", "contact_org": "US Geological Survey", "contact_email": "bbloss@usgs.gov", "contact_phone": "3032361858", "keywords": "time-domain electromagnetics; transient electromagnetics; geophysical surveying; Geophysics; near-surface mapping", "description": "Ground-based transient electromagnetic (TEM) data were acquired in selected locations around Belle Creek, Montana to define the resistivity structure of the near surface. Data were acquired using the ABEM WalkTEM system (Guideline Geo Ab, Sundbyberg, Sweden). TEM data were processed and numerically inverted to derive one-dimensional resistivity structure using SPIA (Aarhus Geosoftware, Aarhus, Denmark).\r\n\r\nThis release includes raw and processed TEM data and resistivity models for each data location using the following structure:\r\n\r\n\u251c\u2500\u2500 Ground-based_transient_electromagnetic_data_and_resistivity_models_for_SubTER_BelleCreek_2017-2018.xml\r\n\u251c\u2500\u2500 SBC_TEM_2019_SoundingLocationsModels.gdb.zip - file geodatabase with all models and plots attached. This is a mirror of the contents of the model directory.\r\n\u2514\u2500\u2500 Ground-based_transient_electromagnetic_data_and_resistivity_models_for_SubTER_BelleCreek_2017-2018.zip\r\n \u251c\u2500\u2500 Data\r\n \u2502\u00a0\u00a0 \u251c\u2500\u2500 SBC_USF - raw data\r\n \u2502\u00a0\u00a0 \u2502\u00a0 \u251c\u2500\u2500 USF_format_description.pdf - manual describing the USF file format\r\n \u2502\u00a0\u00a0 \u2502\u00a0 \u251c\u2500\u2500 SBC_SoundingID-USF_lookup.csv - table describing the USF file naming convention and channel mapping\r\n \u2502\u00a0\u00a0 \u2502\u00a0 \u2514\u2500\u2500 *.usf files - raw, unprocessed data files\r\n \u2502\u00a0\u00a0 \u2514\u2500\u2500 SBC_TEM - processed data\r\n \u2502\u00a0\u00a0 \u00a0 \u251c\u2500\u2500 AarhusInv_manual.pdf - manual describing the TEM file format\r\n \u2502\u00a0\u00a0 \u00a0 \u2514\u2500\u2500 *.tem files - processed data files\r\n \u2514\u2500\u2500 Models\r\n \u251c\u2500\u2500 SBC_Model_Plots - plots of the data and the models for each sounding location\r\n \u251c\u2500\u2500 TEM_model_data_dictionary.csv - data dictionary describing tabulated models\r\n \u2514\u2500\u2500 SBC_TEM_models.csv - tabulated models\r\n", "doi": "10.18141", "creator_id": "acb1c858-8427-449f-af59-0b4a52e1d1c8", "timestamp": "2020-12-04 16:38", "product_type": null, "medium_code": null, "access_limitation": null, "released_date": null}, "submission_authors": [{"email": "bbloss@usgs.gov", "fullname": "Benjamin R. Bloss"}, {"email": "wmcalile@mymail.mines.edu", "fullname": "Wallace Anderson McAliley"}, {"email": "tirons@mtech.edu", "fullname": "Trevor Irons"}, {"email": "ygli@mines.edu", "fullname": "Yaoguo Li"}, {"email": "nathan.moodie@m.cc.utah.edu", "fullname": "Nathan Moodie"}, {"email": "rkrahenb@mines.edu", "fullname": "Richard Krahenbuhl"}, {"email": "mpace@usgs.gov", "fullname": "Michael D.M. Pace"}, {"email": "kzamudio@usgs.gov", "fullname": "Katrina D. Zamudio"}]}