Your browser is not recommended for EDX, we suggest using the latest version of Google Chrome.

Coolside Waste Management Research. Final report, April 23, 1991--June 30, 1996

License(s):

Other (Open)

This study was initiated during a successful test of the Coolside flue gas desulfurization technology at Ohio Edison`s Edgewater generating station in 1991. Coolside is a lime duct technology which is installed on the downstream side of the last heat exchanger. As tested by Ohio Edison, it also employs an alkali reagent, in this case NaOH, to enhance sulfur capture. The overall goal of this study was to develop sufficient chemical and physical data to insure the environmentally safe disposal of the material. This final report summarizes the important aspects of the project, but it does not present all of the data that was produced. Further details may be found in the monthly and quarterly reports that were filed with the Morgantown Energy Technology Center. This report is organized into six chapters which present the important conclusions of the principal areas of investigation.

Followers: 0

Citation (Click to Copy)

Data and Resources

    Gathering Resources...

Keywords

Additional Info

Field Value
Last Updated September 29, 2016, 15:36 (LMT)
Created September 29, 2016, 15:36 (LMT)
Citation Roy Long, Coolside Waste Management Research. Final report, April 23, 1991--June 30, 1996, 2016-09-29, https://edx.netl.doe.gov/dataset/coolside-waste-management-research-final-report-april-23-1991-june-30-1996
Netl Product yes
Poc Email Roy.long@netl.doe.gov
Point Of Contact Roy Long
Program Or Project KMD
Publication Date 1998-12-31