This report describes part of a continuing effort to develop methods for determining S species in retort gas. In particular, previous experiments have evaluated various column types for their abilities to separate the various S compounds from each other as well as from interfering hydrocarbons. Fluorescence quenching of the S emission in the flame photometric detector by hydrocarbon species found in retort gas has also been examined. Such studies indicated that a standard, single flame FPD should be adequate for monitoring H2S in conjunction with an acetone-washed Porapak QS packed column, a combination used in this study. This column was selected also because it is supposedly inert to water vapor, a major component of retort gas and one which cannot be tolerated by many types of packing material.

Followers: 0

Citation (Click to Copy)

Data and Resources

    Gathering Resources...

Keywords

Additional Info

Field Value
Last Updated September 29, 2016, 22:08 (LMT)
Created September 29, 2016, 22:08 (LMT)
Citation John Wallace, Elizabeth Sexton ---- Roy Long, EVALUATION OF A GAS CHROMATOGRAPHIC METHOD FOR MONITORING H2S IN RETORT GAS--RESULTS OF A FIELD TEST AT THE LOW VOID VOLUME RETORT, 2016-09-29, https://edx.netl.doe.gov/dataset/evaluation-of-a-gas-chromatographic-method-for-monitoring-h2s-in-retort-gas-results-of-a-field-tes